EEXI Calculator
Use our EEXI calculator to obtain indicative results for your vessel's compliance with the new regulation.
The results obtain by running the calculator are indicative and should not be used directly for reporting. Read our disclaimer for the calculator
Contact information
Vessel Basic Data
Vessel M/E and A/E Data
Vessel Speed & Other Data
Personal Information
Please fill your contact information. For the details of collection and use of this information please refer to our privacy notice
First Name *
Last Name *
Job Position *
Company *
E-mail Address *
Vessel Basic Data
Fill the vessel's basic data
Vessel Name
Vessel Type*
-- select an option --
Bulk Carrier
Tanker
Container
LNG Carrier
General Cargo
Ship DWT Capacity [t]*
🛈
Deadweight at summer load line draught
VESSEL M/E AND A/E DATA
Fill the M/E and A/E data in accordance to the provided hints
M/E Maximum Continuous Rating (MCR) [kW]*
🛈
Fill the total power of all the propulsion means
Is Power Limitation Applied?*
🛈
Fill yes if any propulsion power limitation is applied
-- select an option --
Yes
No
M/E Limited Continuous Rating (MCRlim) [kW]*
🛈
Fill the power which the vessel is limited to by technical means
Not valid option for this configuration
M/E specific fuel consumption at 75% of MCR or 83% of MCR
lim
[gr/kWh]*
🛈
Fill the M/E specific fuel consumption as reffered in NOx Technical file or by the manufacturer. If is not available, fill 190 g/kWh.
M/E fuel used for the determination of SFC*
🛈
Fill the fuel type used for the determination of the SFC. If is not available fill HFO
-- select an option --
Diesel/Gas Oil (DMX - DMB)
Light Fuel Oil (RMA - RMD)
Heavy Fuel Oil (RME - RMK)
Liquefied Natural Gas (LNG)
A/E specific fuel consumption at 50% of MCR
lim
[gr/kWh]*
🛈
Fill the A/E specific fuel consumption as reffered in NOx Technical file or by the manufacturer. If is not available, fill 210 g/kWh.
A/E fuel used for the determination of SFC*
🛈
Fill the fuel type used for the determination of the SFC. If is not available fill HFO
-- select an option --
Diesel/Gas Oil (DMX - DMB)
Light Fuel Oil (RMA - RMD)
Heavy Fuel Oil (RME - RMK)
Liquefied Natural Gas (LNG)
VESSEL SPEED DATA
Fill the Vessel's speed & other data in accordance to the provided hints
Select the method for calculation of vessel reference speed*
🛈
In order to calculate the EEXI value, the reference vessel speed should be provided. This speed can be obtained form sea trials, numerical calculations or the EEDI technical file. If none of those are available, the speed is estimated by an approximate value.
-- select an option --
Approximate Speed
Actual Speed
Approximate Vessel Speed [knots]
Not valid option for this configuration
Reference speed at capacity and P
ME
[knots]*
🛈
Fill the validated reference speed at summer load line DWT (or 70 % DWT for containers). This speed should be validated in accordance to the rules.
Not valid option for this configuration
Is the vessel built in accordance to CSR?*
🛈
Fill yes if the ship is constructed in accordance to CSR rules
-- select an option --
No
Yes
Not valid option for this configuration
Lightship [tons]*
🛈
If the ship was built in accordance with the CSR rules, the Lightship is to be provided.
Not valid option for this configuration
Is the vessel a chemical carrier?*
🛈
Fill if the ship is a chemical carrier
-- select an option --
No
Yes
Not valid option for this configuration
Cargo Cubic Capacity [m
3
]*
🛈
If the ship is a tanker or abulk carrier, acargo cubic capacity should be provided.
Not valid option for this configuration
EEXI CALCULATION RESULTS
Below you will find the
Attained EEXI
value and the
Required EEXI
value. In order for a ship to comply with the rule, the attained value should be less than the required value.
The attained EEXI of the vessel is [tCO2/tknots]:
The required EEXI for the vessel is [tCO2/tknots]:
There is no requirment for EEXI compliance for this kind of vessel
The result of EEXI compliance is:
We are done!Please note that the above results are indicative and should not be used directly for submiting the technical file.
If you are intrested in calculating and reporting the technical file for EEXI, please contact us at
Send Email